AirSource Technologies’ offices are located in the
metropolitan Kansas City area (Shawnee, KS). From this hub, we are able to
respond quickly and cost effectively to our core service area that includes
Missouri, Kansas, Iowa, Illinois, Nebraska, Oklahoma, Arkansas, and Texas.
We have successfully responded to project opportunities outside of this core
service area as well (we’ve recently tested in Maine, Pennsylvania, New
York, Ohio, and Washington, for example) so we do not rule out participation
in any project, so long as it is within our capabilities.
Within our 5500 square-foot facility, we have offices, a laboratory, an
equipment maintenance and calibration area, a project staging area, C.E.M.
instrumentation trailer bays, and equipment, records, and supply storage
areas.
 |
Stack Sampling Equipment |
 |
AirSource is
capable of providing up to 20 complete sampling trains for all standard CFR
40, Parts 51, 60, 63 and B.I.F. methods as well as many specialized trains
per client requests.
Some examples
include Particulate, Dioxin/Furan Compounds, Multiple Metals, Hexavalent
Chromium, Volatile Organics (VOST), Semi-Volatile Organics (including PAH’s,
pesticides, herbicides, PCB’s, etc.), HCl/Cl2/HF (Method 26/26A), Sulfur
Compound Speciation (Method 8), Formaldehyde (CARB 430),
and many
others.
Redundancy of
equipment allows for sampling of multiple trains simultaneously whether for
a common constituent at both inlet and outlet of pollution control devices,
or for several different constituents at the same time. In addition,
redundancy provides time saving backup of key equipment should an instrument
fail in the field.
|
 |
Nutech Model
2010 - Method 5 stack sampling systems |
|
 |
Multiple
Sampling Probes - varying lengths (3 ft., 5 ft., 7 ft., 10 ft., 20 ft.),
including water-cooled models for high temperature operations |
|
 |
VOST
Sampling Trains |
|
 |
In-Stack
Filter Apparatus (Method 17); both Teflon-lined and glass |
|
 |
Hydrochloric
acid/chloride ion train |
|
 |
Hexavalent
chromium train |
|
 |
Orsat and
Fyrite Equipment |
|
 |
PM5 PM10
Cyclones (Particulate matter less than 5 or 10 micron) |
|
 |
Particle
sizing cascade impactor |
In addition to
the major equipment referenced above, AirSource has an extensive inventory
of support and ancillary equipment and materials such as sampling umbilical
lines, nozzles (quartz, stainless steel, glass), impinger boxes, heated
filter boxes, glassware, balances, chemicals, tools, communication devices,
safety equipment, etc.
|

|
In-Site Capabilities |
|
Volatile Organic Compounds by Gas Chromatography (GC)
Hazardous Air Pollutants by Fourier Transform Infrared Spectrometry
(FTIR) and Gas Chromatography/Mass Spectroscopy (GC/MS)
Aldehyde Group Compounds by High Performance Liquid Chromatography (HPLC)
Hazardous Organic NESHAP (HON) TRE Projects Involving Field and/or
Laboratory GC
"Real-Time" Field Determinations of Total Particulate and PM10
|
|
|